Assay Method Information

Assay Name:  AT2 Receptor Binding Assay
Description:  15 μL of [125I]CGP 42112A, at a final concentration of 0.05 nM was added to wells of assay plate.Membranes were dispersed using a 21 gauge needle and diluted to the appropriate protein concentration in assay buffer.120 μL membrane suspension (15 μg protein/well) was added to wells of assay plate.Assay plates were incubated at RT for 2 h.Incubations were stopped by rapid filtration through Multiscreen GF/C plates (Millipore, cat. no. MAFCNOB50), using Multiscreen HTS vacuum manifold (Millipore, cat. no. MSVMHTS00) after pre-wetting filters with wash buffer.Filters were washed five times with ice-cold wash buffer.Filters were dried at RT.50 μL MicroScint 40 was added to each well.Bound 125I was determined using MicroBeta scintillation counter in Trilux mode, for 1 min per well.
Affinity data for this assay
 

If you find an error in this entry please send us an E-mail