Assay Method Information

Assay Name:  Electrochemiluminescence (ECL)-based Immunoassay
Description:  To measure γ-secretase activity, membranes were incubated at 37° C. for 1 h in 50 μL of buffer containing 20 mM Hepes (pH 7.0) and 2 mM EDTA. At the end of the incubation, Aβ 40 and Aβ 42 were measured using an electrochemiluminescence (ECL)-based immunoassay. Aβ 40 was identified with antibody pairs TAG-G2-10 and biotin-W02, while Aβ 42 was identified with TAG-G2-11 and biotin-4G8. The ECL signal was measured using an ECL-M8 instrument (IGEN International, Inc.) according to the manufacturer's instructions.
Affinity data for this assay
 

If you find an error in this entry please send us an E-mail