Assay Name:  H1 and 5-HT2A Binding Assay
Description:  1 μl of a compounds of the present disclosure and either reference compound (Table C) were transferred to assay plates. 1 μl of 0.2 mM Ketanserin or Pyrilamine was transferred to an assay plate according to the plate map for nonspecific binding (Low control: LC). 1 μl of DMSO was transferred to an assay plate according to plate map for total binding (High control: HC).100 μlof membrane stocks were dispensed into the plates, following the plate map. 100 of radio ligand was added. The plates were sealed and shaken at 300 rpm at room temperature for 1 hour. The Unifilter-96 GF/C filter plates were soaked with 50 of 0.3% PEI per well for at least 0.5 hour at room temperature.When the binding assays were complete, the reaction mixture was filtered through GF/C plates using Perkin Elmer Filtermate Harvester, and then each plate was washed 4 times with cold wash buffer. The filter plates were dried for 1 hour at 50 degrees. After drying, the bottom of the filter plate wells were sealed using Perkin Elmer Unifilter-96 backing seal tape. 50 μl of Perkin Elmer Microscint 20 cocktail was added. The top of the filter plates were sealed with Perkin Elmer TopSeal-A sealing film.